DOMINUS NL

Nitrogen Generator
Designed for Food Packaging and inertization in Chemical, Thermal, and Biological Treatments

APPLICATIONS

– Food packaging and bottling, especially for wine, oil, fruit juices, and mineral water
– Inertization of chemical and biological processes
– Electronic soldering

Description

Use of high-quality CMS resulting from 40 years of research and testing in collaboration with specialists in the field.
Automated filling system to ensure higher density and better generator reliability than conventional systems.
Minimised air and energy consumption thanks to the Eco mode included: automatic adaptation of the process time and modulation of the phases in proportion to the nitrogen withdrawn.
Automatic stand-by mode if the nitrogen flow generated is greater than the flow drawn in.
Self-adjustment of the process to maintain the desired degree of purity.
Continuous availability (24 hours a day, 7 days a week).
No need for supervision and/or user activity thanks to pre-set operating programs
Nitrogen shut-off valve: flow management according to purity and pressure levels compatible with customer requirements. Symbiotic use with other supply sources.
Long-life, high sensitivity oxygen analyser.
Touch screen display.
Maximum flexibility of communication between the generator and the external environment: MODBUS, MQTT, http protocols.
From any device connected to the web, you can access the Claind4You portal, which allows you to control the generator remotely, independently and securely.

OPTIONALS

FLOW METER

- Digital flow meter with signal connected to the generator.

COMPRESSED AIR MONITOR

- Continuous air quality monitoring to protect the generator.

- Temperature and dew point sensors.

- Automatic non-compliance mode in case of compressed air contamination.

Technical specifications

MODEL Outgoing nitrogen flow* [ Nm³/h ]
  99,999% 99,99% 99,9% 99,5% 99% 98% 97%
DOMINUS NL 1 12 17 26 35 40 50 58
DOMINUS NL 2 23 35 52 70 80 101 116
DOMINUS NL 3 35 52 78 105 119 151 173
DOMINUS NL 4 47 69 104 140 159 202 231
DOMINUS NL 5 58 86 131 176 199 252 289
DOMINUS NL 6 70 104 157 211 239 303 347
               
AIR/N2 5,10 4,20 3,20 2,65 2,45 2,20 2,05

* The flow capacity refers to inlet air nominal conditions: pressure of 8,5 bar , CMS temperature of 20 °C.

 

TECHNOLOGIES ADOPTED PSA CLAIND
INLET AIR SPECIFICATIONS

• Air pressure: min 6,5 / max 13 bar

• Quality: dry, clean, exhalation free. The inlet air must meet

the specifications ISO 8573ISO 8573-1  Classe 1.4.1

NITROGEN OUTLET PRESSURE

Given the pressure P of the inlet air, the pressure of the

nitrogen generated is lower than 1,5 bar

MOISTURE CONTENT AT OUTLET -50°C Dew Point ATP
ELECTRICAL SUPPLY

230 Vac ± 10% 50 Hz

115 Vac ± 10% 60 Hz

POWER RATING 100 W
INDEX OF PROTECTION IP 20
MAX NOISE ≤ 96 dBC (measured at 1 meter, SPD not required)
OPERATING TEMPERATURE 5 ÷ 40°C
PNEUMATICAL CONNECTIONS G 1 ½” F - Inlet air and N2 to Tank
DIMENSIONS                                                                               
                                                                                               Height    239 cm
                                                                                                Width 77 cm
                                                                                                Depth

NL 1: 65 cm         NL 2: 94 cm        NL 3: 122 cm

NL 4: 152 cm       NL 5: 181 cm      NL 6: 210 cm

WEIGHT

NL 1: 800 kg        NL 2: 1040 kg     NL 3: 1280 kg

NL 4: 1520 kg      NL 5: 1760 kg     NL 6: 2000 kg

Models

  • DOMINUS NL 1
  • DOMINUS NL 2
  • DOMINUS NL 3
  • DOMINUS NL 4
  • DOMINUS NL 5
  • DOMINUS NL 6

Download